Sensing range
|
60
... 500 mm
|
Unusable area
|
0
... 60 mm
|
Standard target plate
|
100
mm x 100 mm
|
Transducer frequency
|
approx.
380 kHz
|
Response delay
|
for
factory setting
minimal (EM; NONE): ≤20 ms (2 measuring cycles)
default
(EM, MXN, 5, 2): ≤40 ms (4 measuring cycles)
dynamic (EM, DYN): ≤30 ms (3
measuring cycles)
|
Indicators/operating means
|
LED yellow
|
switching
state switch output 1
switching state switch output 2
|
LED red/green
|
solid
green : "Power on", flashes during standby operation
red flashing : "Error", (e. g.
background noise level too high)
|
Electrical specifications
|
Operating voltage
|
20
... 30 V DC , ripple 10 %SS
|
No-load supply current
|
≤
60 mA
|
Interface
|
Interface type
|
RS
232, 9600 bit/s, no parity, 8 data bits, 1 stop bit
|
Input/Output
|
Synchronization
|
1
synchronous connection, bidirectional
0-level: -UB ... (-UB + 1 V), 1-level: (-UB + 5 V) ... +UB
|
|
Pulse
length
|
≥ 100 μs
|
|
Pause
length
|
≥ 2 ms
|
Synchronization frequency
|
≤
80 Hz , with external synchronisation
|
Output
|
Output type
|
2
switch outputs PNP, NO/NC
|
Rated operating current
|
200
mA , short-circuit/overload protected
|
Voltage drop
|
≤
3 V DC
|
Resolution
|
<
1 mm
|
Repeat accuracy
|
≤
0.1 % of full-scale value
|
Range hysteresis
|
≤
1 % of the set operating distance
|
Temperature influence
|
≤
2 %
|
Approvals and certificates
|
UL approval
|
cULus
Listed, General Purpose
|
CSA approval
|
cCSAus
Listed, General Purpose
|
Ambient conditions
|
Ambient temperature
|
-25
... 70 °C (-13 ... 158 °F)
|
Storage temperature
|
-40
... 85 °C (-40 ... 185 °F)
|
Mechanical specifications
|
Protection degree
|
IP65
|
Connection
|
terminal
compartment, ≤ 2.5 mm2 conductor csa
|
Material
|
|
|
Housing
|
PBT
|
|
Transducer
|
epoxy resin/hollow glass sphere mixture; polyurethane
foam
|
Mass
|
180